Operating Manual Compact Weather Station
18 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
6.15 Precipitation Type
Sampling rate Event-dependent on reaching the response threshold
Response threshold 0.01mm
Follow-up time 2 minutes
Request channels:
UMB Channel
Measurement Variable (unsigned char)
Coding
700
Precipitation Type
0 = No precipitation
60 = Liquid precipitation, e.g. rain
70 = Solid precipitation, e.g. snow
Note: A detected precipitation type remains valid for 2 minutes after the end of the
precipitation event. In order to record precipitation types which only occur for a short period
(e.g. short-term rain), the request time should be at least 1 minute.
Ice, hail and sleet are transmitted as rain (60).
6.16 Heating Temperature
Sampling Rate 1 Minute
Units °C; °F
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float)
min
max
Unit
112
Heating Temperature Wind Sensor
-50.0
150.0
°C
113
Heating Temperature Precipitation Sensor
-50.0
150.0
°C
117
Heating Temperature Wind Sensor
-58.0
302.0
°F
118
Heating Temperature Precipitation Sensor
-58.0
302.0
°F
6.17 Global Radiation
Sampling Rate 1 minute
Generation of average values 1 10 minutes
Unit W/m²
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float)
min
max
unit
900
920
940
960
Global Radiation
0.0
1400.0
W/m²