19
PROSEAR™ 2 BURNER
It’s easy to keep your
ProSear™ 2 burner operating
at peak performance. Just run
it on “HI” with the hood open
for 5 minutes after each use to
burn away any food particles
or drippings.
Any ash accumulation on the
burner screen can be removed
with a light brush or vacuum
… BUT WAIT UNTIL THE
BURNER IS COOL!
TROUBLESHOOTING YOUR LYNx GRILL
BEFORE YOU CALL FOR SERVICE
Please check a few things before calling for service:
► Is there fuel supplied to the grill?
► Is the main shut-off valve open?
► Are you using the correct type of fuel? (LP or Natural Gas) (See INDEX: “Gas Requirements” for further
details.)
► Is your propane cylinder empty? Have you recently relled the propane cylinder? If so, is the
connection tight?
► Have you opened the valve on the propane cylinder?
► Is the grill plugged in to a live electric circuit?
If you’ve checked the above items, review the trouble-shooting list below before calling for Lynx for
service.
Heat Shield Removed,
Orice/Venturi Position
Every 3 to 6 months, remove
the burner and inspect the
venturi (inlet) and orice to
ensure that they’re free of
obstructions.
Food debris on the inside
of the burner can be gently
shaken out. Do not touch
the ceramic surface.
Inside View, Orice all
the way into venturi
When re-installing the
ProSear™ 2 burner, be sure to
correctly position the burner.