1014
Sudden Change
Of Speed
Auto-
Reset
20%
10 rpm
0.1 sec.
The controller looks
for a % change in
speed bounded by
a minimum RPM
change in a certain
amount of time. If
both conditions are
met, then the drive
will disable.
Fan Speeds Up
Suddenly
Fan “Twitches”
Fan Will Not
Run
Fan Stops
Suddenly
1. Ensure that blade length is properly
set
2. Perform a drive calibration
3. Conrm incoming power is within
fan’s specications
4. Conrm motor values. Perform power
calibration if possible/necessary
1015
Tilt Limit
Exceeded
Auto-
Reset
+/- 5 °
Fan Wobbles
Fan Stops
Running
Fan Will Not
Start
1. Conrm that the tilt is below 5
degrees
2. Conrm that fan or structure is not
wobbling
3. Conrm that locking hardware on
mount is tight
4. Add guy wires if necessary
5. Disable tilt if guy wires are installed
1016
Vibration Limit
Exceeded
Auto-
Reset
Fan Vibrates
Fan Wobbles
Fan “Twitches”
1. Conrm that fan or structure is not
wobbling
2. Conrm that locking hardware on
mount is tight
3. Add guy wires if necessary
1017
Keep-Alive
Timeout
Auto-
Reset
10s
Fan Randomly
Stops
Fan Will Not
Start
1. Conrm whether touchpad was
unplugged or not
2. Conrm that CAT5 is under 100ft
3. Conrm that CAT5 is from factory and
has not been modied
4. Conrm that CAT5 is shielded
5. Conrm that repeaters are properly
installed on the network
6. Double check network splices
7. Plug touchpad directly into board
Troubleshooting