WARNING - DANGER OF SLIDING!
During cleaning of working area, be careful to working residuals and liquids left over the floor all
around the machine: they can be dangerous for sliding of the operator.
17.2 CLEANING OF THE MACHINE (DAILY)
The machine and working area must be kept clean from working scraps and anything that could hamper the
working cycle or access to the machine itself. The machine must be cleaned every day. Make sure that no ma-
terial not needed by the machine can gather on it preventing safe operation and causing danger to the operator
during the normal working cycle .
17.3 CLEANING OF THE GUIDES (WEEKLY)
Sliding guides and bars must be kept clean from working residuals: they can obstacle correct machine move-
ments and damage machine efficiency. Do not use detergents or lubricants.
ELECTRICAL CABLES CHECK
Check the condition of the electric cables. Make sure there are no signs of wear, scrapes, etc.
18.1 DRILLS DO NOT WORK
18. COMMON FAILURES: REASONS AND REMEDIES
Some failure causes can be eliminated directly by the operator, other by qualified personnel only.
17. MAINTENANCE
17.1 ORDINARY MAINTENANCE
PROBABLE REASON ACTION
A - the motor does not work
B - the motor is out of service
- push the motor start push button
- release the emergency push button and/or check fuse
- check air pressure value (to turn on the pressure sensor)
- replace the motor
PROBABLE REASON ACTION
A - possible failure of:
- gears and/ or keys
- drive joint
- replace them or call technical service
ATTENTION:
BEFORE MAKING ANY INTERVENTION IT IS OBLIGATORY TO FOLLOW CAREFULLY
THE INSULATION PROCEDURE
AN ADEQUATE MAINTENANCE IS A CRUCIAL FACTOR FOR A LONGER LIFE OF THE
MACHINE, AND TO OBTAIN OPTIMAL WORKING CONDITION OF THE MACHINE ITSELF.
ALL THE MAINTENANCE OPERATIONS MUST BE DONE WITH THE MACHINE TURNED
OFF. WEAR ALWAYS PROTECTIVE GLOVES AND FACE-SHIELD
17.4 EXTRAORDINARY MAINTENANCE
− Check electric system safety
− Check the clamping of the various mechanical components.
− Check the lubricant oil level in the filter unit and top up if necessary.
− Make sure the machine is lubricated regularly.
− Check air pressure value: the pneumatic power supply must give air at a pressure
value of 6 bar
− Check sludge: sludge and air impurity deposit into the transparent cup of air treatment group
MAINTENANCE
18.2 THE MOTOR WORKS BUT THE DRILLS DOES NOT