EasyManua.ls Logo

Magicar M100AS - Set-up and Other Functions - Time Backup and Gas Residue; Time Information Backup; GAS (LPG) Option Set-up; Remote Start for Gas Residue Burn-off

Magicar M100AS
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
S
e
t
-
up
a
nd
O
t
h
e
r
F
un
c
t
i
o
n
s
S
e
t
-
up
a
nd
O
t
h
e
r
F
un
c
t
i
o
n
s
33
Time information backup
1. It saves time information (current time, start-up reservation time and alarm time)
in the status where power has not been supplied to remote (at a time of replacing
batteries). If the power is supplied again, users do not have to re-adjust the time
information.
2. Remote default is set in the status when the time information backup is released.
In order to set up the time information backup for the remote, users need to execute
the menu of the remote once or more.
After users execute the menu ((2+3)-), the time information backup is automatically
executed.
3. Cautions at a time of replacement of batteries
In order to use the time information backup function more effectively, press button
No.4 of the remote before and at a time of the replacement of the batteries (commu-
nication with the main not needed at that time) to back up more accurate time infor-
mation.
Door Open Indicating Function
The parking lights will flash to indicate that the door is open.
(See page 39 - for the set-up procedure for the main options)
GAS(LPG) Option Set-up
Bu
r
n
i
ng off gas
r
es
i
d
ue
i
n
t
he syste
m
:
In Turbo Mode, if Key is turned OFF but the GAS valve is not shut off, then
the engine will be turned off in 4 minutes without burning off the gas
residue.
In Turbo Mode, the remote will show the engine running to burn off the gas
residue.
No
t
e
Auto Transmission Car
- While engine is running, shut off the gas valve and wait. Then turn off the key after
the gas residue was burnt off.
- Activating Turbo Mode will be a convenient way of burning off the gas residue
since engine will continue running like a manual transmission vehicle until the gas
residue is burnt off. See below.
Manual Transmission Vehicle
Turn off the key first then shut off the gas valve. Engine will continue running until
the gas residue is burnt off. If you open and close the door while engine is still run
ning, the remote start reservation is also completed.
Remote Start
After remote start is completed, the ignition wire will continue to be powered for 4
more minutes (or 4 minute and 20 seconds if a door opens while engine is running)
by the system to make sure the gas residue is burnt out.

Related product manuals