Outline Dimensions
Standard Rigid Probe Flexible Probe
Housing AB
CDE F CD EF
NEMA 4X/7/9 3.87 5.93 10.89 2.44 13.44 4.11 12.33 4.71 13.44 4.11
Die-cast alum. (98) (151) (276) (61) (341) (104) (313) (119) (341) (104)
50-604 Kotron Model 804 Sentinel II RF Level Transmitter
26
.375 (10)
.50 (13)
.625 (16)
O
ptional
mounting
flange
2.75
(70)
3
/4" NPT
3.23
(82)
3.00
(76)
4.63
(
118) Dia.
2
I.L.
Figure 14
Remote Mount with Standard Rigid Probe
3.3 Specifications
3.3.2 Dimensional (cont.)
inches (mm)
Conduit
Connections
G
NEMA 4X/7/9
3
4" NPT
(remote probe housing)
Single conduit
NEMA 4X/7/9
1" NPT
Dual conduit
NOTES:
Allow 8 inches (203 mm) overhead clearance for cover
removal.
Standard process connection is
3
4" NPT. Consult probe
brochure (Magnetrol 50-125/STI 95-133) for flange and
other probe connections.
Probe/amplifier connecting cable to be shielded twisted
pair 22-gauge stranded conductors; Magnetrol/STI part
number 009-7146-001, 2500 feet (760 m) maximum;
800 feet (240 m) maximum for intrinsically safe models.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetrol Kotron Sentinel II 804 Series and is the answer not in the manual?

Magnetrol Kotron Sentinel II 804 Series Specifications

General IconGeneral
BrandMagnetrol
ModelKotron Sentinel II 804 Series
CategoryTransmitter
LanguageEnglish

Related product manuals