Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
135
Turn ignition ON
Clear the error codes
and verify
Turn ignition OFF
Ensure that the main relay is
inserted properly in the
connector
Remove the relay
Give 12 volts to terminal 86
and ground the terminal 85
A clicking sound to be heard
1
Is the clicking
sound heard?
Turn ignition OFF
Replace the main relay
with a new one
Check and confirm the battery
voltage is more than 8 Volts
Check and confirm the 30 Amp
Maxi fuse is working properly
Connect the smart tester
Turn the ignition ON
Initialize the diagnostic tool
Record the DTC and clear
Turn ignition OFF
Turn ignition ON
Verify if P121A or P121B is
present
Is P121A or
P121B present?
NO
YES NO
Go to Step2
YES