Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
273
Minimum rail pressure required to start the engine (while cranking) - 275 to 325 bar
Minimum cranking rpm required to start the engine - 120-140 rpm
.
Note -
Any malfunctioning of the pre supply pump will not be registered as a DTC .If no error
codes are registered and engine is not starting , malfunctioning of the pre supply pump
may also be one among the causes for engine not starting
PRESSURE CONTROL VALVE (PCV)
Minimum Resistance - 3.42 Ohms
Maximum Resistance - 3.78 Ohms
Nominal Resistance – 3.6 Ohms
Measured at 20° C