Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
149
SYSTEM CHECK LAMP – POWER STAGE FAULT STATUS
NORMAL OPERATION
When the ignition is switched ON, the system check lamp will glow ON for 02 seconds and will get switched OFF
if no error is set in the ECU.
DTC Detecting Condition Probable Causes
When the ignition is switched ON, the system
lamp does not glow ON or glows continuosly
Open, short to battery or short
to ground of the system check
lamp wiring harness or
connectors
CIRCUIT
(P8)
Sl No DTC Description
1
P1656 System lamp no load
2
P1657 System lamp excess temperature
3
P1654 System lamp short circuit to battery
4
P1655 System lamp short circuit to ground
IC 1F:10