EasyManua.ls Logo

Mahindra Maxximo Mini Van Vx 2012 - Environment Pressure Sensor

Mahindra Maxximo Mini Van Vx 2012
274 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
187
ENVIRONMENT PRESSURE SENSOR
Sl No DTC DESCRIPTION
1
P0108 Environment Pressure Sensor voltage above upper limit
2
P0107 Environment Pressure Sensor voltage below lower limit
LAMP STATUS
Engine check lamp OFF
FAULT REACTION
No reaction
TEST PROCEDURE
1.
Switch ON Ignition.
2.
Using ‘Smart Tester’, clear the ECU faults.
3.
Switch OFF Ignition key and wait for 2 minutes.
4.
Switch ON Ignition.
5.
Using smart tester check whether any of the above mentioned fault is present.
6.
If fault is still present, switch OFF ignition.
7.
Replace the ECU with a new one (follow the ECU replacement procedure) and repeat steps 4 & 5.
8.
If fault is not present in the new ECU, then the old ECU is defective and has to
be sent back to M&M
Note : Please send CrFr and get approval before step 8

Table of Contents