188
LAMP STATUS
Engine check lamp ON
Sl No DTC DESCRIPTION
1
P1900 Diagnostic fault check to report the NTP error in ADC monitoring
2
P1901 Error during SOP test; uncertain cause (defective injector or shut-
off path).
3
P1902 Diagnostic fault check to report the ADC test error
4
P1903 Diagnostic fault check to report the error in Voltage ratio in ADC
monitoring
5
P1904
Diagnostic fault check to report errors in query-/response-
communication
6
P1905
interrupted SPI communication
7
P1906
Diagnostic fault check to report multiple error while checking the
complete ROM-memory
8
P1907
Loss of synchronization sending bytes to the MM from CPU.
9
P1908
Error trying to set MM Response time
10
P1909
Too many SPI errors during MoCSOP execution.
11
P1910 Diagnostic fault check to report the error in overvoltage
monitoring
12
P190A
Expiration of the waiting time due to hardware not active
13
P190B Error in the check of the shut-off path test of the under voltage
detection
14
P190C Diagnostic fault check to report that WDA is not working correct
15
P190D OS timeout in the shut off path test. Failure setting the alarm task
period.
16
P190E
Time out while requesting an injection
17
P190F
timeout in the shut off path test