Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
190
LAMP STATUS
Engine check lamp ON
FAULT REACTION
ECU Reset / Injection cut off above 1500 RPM / Engine shut off above 1720 RPM
Sl No DTC DESCRIPTION
1
P1912
Impermissible offset between the engine speed of level 2 and level
1
2
P1913
Error in the plausibility of the injection quantities
3
P1914
Error in the plausibility of the start of energising angles
4
P1915
Error in the plausibility check of the ZFC energising times.
5
P1916
Error in the plausibility of PoI2 efficiency.
6
P1917
Error in the PoI2 shut-off.
7
P1639
State of overrun detection
8
P1918
error due to injection quantity correction
9
P1919
plausibility error in rail pressure monitoring