252
RESISTANCE OF THE ATS AT VARIOUS TEMPERATURE OF THE ATMOSPHERE
Temperature Min Resistance Max Resistance
20 °C 2.371 K 2.729 K
40°C 1.069 K 1.231 K
80°C 0.306 K 0.354 K
Step 6
Ignition OFF
Air temperature sensor
connector
DISCONNECTED
Check the resistance
between pin 1 and pin 2
of the Air temperature
sensor
Is resistance
0.306 to 0.354
K
at
80
°
C
NO
Ignition OFF
Replace the Air
temperature sensor with a
new one
Clear the DTC and verify
Ignition OFF
Check for poor terminal
contact because of damage
in the coolant
temperature sensor or pin
bend or pin oxidation and
repair if necessary
Clear the error codes and
verify
YES