EasyManua.ls Logo

Mahindra Maxximo Mini Van Vx 2012 - Page 260

Mahindra Maxximo Mini Van Vx 2012
274 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
260
Sl No DTC Description
1
P1536
Demister Circuit open load error
2
P1535
Demister Circuit Short circuit to ground
3
P1534
Demister Circuit
Short circuit to battery
4
P1537
Demister Circuit over temperature Power Stage error
NORMAL OPERATION
When the Demister Switch is pressed the Demister Relay is energized by providing ground to the Demister Blower
Motor Relay which in turn provided 12V supply from the battery to the Demister blower motor at a single speed.
DTC Detecting Condition Probable Causes
Demister circuit short to ground
Demister circuit short to battery
Demister Circuit open load error
Harness or Connectors
Failed Demister Blower
motor Relay
LAMP STATUS
Engine check lamp OFF
FAULT REACTION
Demister Stops working.

Table of Contents

Related product manuals