85
RAIL PRESSURE DEVIATION
Sl No DTC Description
1
P1191
Rail pressure sensor raw value is below minimum offset
NORMAL OPERATION
The ECU monitors the rail pressure in the system has been reduced to the level of the atmospheric pressure during
start up and after run.
DTC Detecting Condition Probable Causes
If the raw value of the rail pressure remains below the threshold
for the time during startup or below the threshold for the time
during after run, the offset is too great in the negative direction
PCV stuck in open condition
LAMP STATUS
Engine check lamp continuosly ON
FAULT REACTION
Engine low idle RPM set at 1200 .
The accelerator pedal will respond but the maximum RPM is set as 2000 with quantity limitations