Voltage type | AC |
---|---|
Frequency | 50 Hz |
Material | Plastic |
Colour | White |
Voltage | 230 V |
Lists ventilation units and their classifications (Object, Comfort, Radio-controlled).
Lists room air controls and their compatibility with ventilation units.
Details on operating keys, switches, and buttons for ventilation units and controls.
Explains how to switch between different operating modes like heat recovery and cross-ventilation.
Information on activating/deactivating demand-driven ventilation based on sensor measurements.
Instructions for setting the ventilation level using control unit buttons or LEDs.
Specific features and operating modes for PP 45 O, K, and RC ventilation units.
Details on the PPB 30 O unit, its suitability for exhaust air rooms, and operating modes.
Information on PPB 30 K/RC units, including integrated humidity sensor and operating modes.
Compatibility and limitations when combining RLS 45 O/K with PP 45 and PPB 30 units.
Explanation of radio-controlled operation using PP 45 RC/PPB 30 RC units and DS 45 RC.
Details the service mode for installer settings and unit setup, including commissioning software.
Information on connecting wired and radio sensors to RLS 45 O/K and RC units.
Procedure for switching ventilation units on/off using room air controls.
Details on the shutter function in PP 45 units for preventing odor and external air entry.
Explanation of heat recovery mode where units alternate supply/exhaust air.
Description of cross-ventilation mode for rapid venting or cooling without heat recovery.
How demand-driven mode improves air quality or dehumidifies based on sensor input.
Details on automatic and system operation modes for PPB 30 K/RC units.
Explanation of automatic mode for PPB 30 K/RC units, independent of RLS 45 K settings.
Describes system operation for PPB 30 K/RC units, synchronized with RLS 45 K or radio controls.
Information on automatic dehumidification strategies and its activation.
How exhaust air mode is configured, including volumetric flow compensation.
Details on configuring intensive ventilation mode based on humidity levels.
Procedure for manual exhaust air mode on PPB 30 O units for full load air extraction.
How to activate manual exhaust air and intensive ventilation for PPB 30 K/RC units.
How to deactivate ventilation level 0 (Off function) for continuous ventilation.
Explanation of the LED display on control units and its configuration.
Details on the sleep mode functionality for specific ventilation units.
Instructions for intermittent ventilation at level 5 for compatible ventilation units.
Information on the external OFF function for switching off all ventilation system units.
Explanation of volumetric flow compensation for exhaust air units in supply air mode.
Explains the different LED indicators on the PP 45 RC / PPB 30 RC units and their meanings.
Overview of EnOcean radio components compatible with the EEP protocol for system integration.
Details on the DS 45 RC radio switch for operating PP 45 RC / PPB 30 RC units.
Information on the PP 45 EO module for enabling radio control with wired RLS 45 K.
Explains the different program levels for radio telegrams and their functions.
Step-by-step guide for teaching-in various radio components like masters, slaves, and sensors.
Instructions for assigning slave ventilation units to a PP 45 RC/PPB 30 RC master unit.
Procedure for teaching-in ventilation unit pairs and radio switches/sensors to the master.
Steps for teaching-in the DS 45 RC radio switch to the master ventilation unit.
Guide for teaching-in radio sensors to the master unit via the TEACH button.
Instructions for deleting previously taught-in radio transmitters from the master unit.
How to configure the ventilation unit to act as a signal amplifier for EnOcean telegrams.
Steps for teaching-in the PP 45 ACT actuator for combining wired exhaust air units with RC units.
Explanation of the LED indicators that signal when air filters need changing.
List of available replacement filters and where to order them from the Maico filter shop.
Detailed steps for removing and inserting air filters in PP 45 ventilation units.
Instructions for cleaning the internal grille, fan, and electronics cover of PP 45 units.
Steps for replacing air filters in PPB 30 units, triggered by the filter change indicator.
Guide for cleaning PPB 30 units, including internal components and external housing.
List of fault messages for RLS 45 O units and their corresponding meanings.
Details of fault messages for RLS 45 K units, including LED indications and error codes.
Explanation of fault messages for PP 45 RC/PPB 30 RC units, indicated by red LED flashes.
Detailed technical specifications, including dimensions, airflow, and power for PP 45 units.
Detailed technical specifications, including dimensions, airflow, and power for PPB 30 units.