Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Maico PP 45 O and is the answer not in the manual?

Maico PP 45 O Specifications

General IconGeneral
Voltage typeAC
Frequency50 Hz
MaterialPlastic
ColourWhite
Voltage230 V

Summary

Preface

Safety

System Components

Ventilation Units/Slide-in Modules

Lists ventilation units and their classifications (Object, Comfort, Radio-controlled).

Room Air Controls

Lists room air controls and their compatibility with ventilation units.

Operating Keys, Displays, LEDs

Operating Keys, Switches/Buttons

Details on operating keys, switches, and buttons for ventilation units and controls.

Changing Operating Mode

Explains how to switch between different operating modes like heat recovery and cross-ventilation.

Switching Demand-Driven Mode On/Off

Information on activating/deactivating demand-driven ventilation based on sensor measurements.

Setting Ventilation Level

Instructions for setting the ventilation level using control unit buttons or LEDs.

Intended Use

System Features

PP 45 O / PP 45 K / PP 45 RC

Specific features and operating modes for PP 45 O, K, and RC ventilation units.

PPB 30 O

Details on the PPB 30 O unit, its suitability for exhaust air rooms, and operating modes.

PPB 30 K / PPB 30 RC

Information on PPB 30 K/RC units, including integrated humidity sensor and operating modes.

Wired Room Air Control RLS 45 O / RLS 45 K

Compatibility and limitations when combining RLS 45 O/K with PP 45 and PPB 30 units.

System Features

Radio System from PP 45 RC / PPB 30 RC Units

Explanation of radio-controlled operation using PP 45 RC/PPB 30 RC units and DS 45 RC.

Service Mode

Details the service mode for installer settings and unit setup, including commissioning software.

Sensors

Information on connecting wired and radio sensors to RLS 45 O/K and RC units.

Operating Ventilation Unit(s)

Switching On and Off

Procedure for switching ventilation units on/off using room air controls.

Shutter

Details on the shutter function in PP 45 units for preventing odor and external air entry.

Heat Recovery Operating Mode

Explanation of heat recovery mode where units alternate supply/exhaust air.

Cross-Ventilation Operating Mode

Description of cross-ventilation mode for rapid venting or cooling without heat recovery.

Demand-Driven Sensor Mode

How demand-driven mode improves air quality or dehumidifies based on sensor input.

Operating Ventilation Unit(s)

Automatic and System Operation Operating Modes

Details on automatic and system operation modes for PPB 30 K/RC units.

Automatic Operating Mode

Explanation of automatic mode for PPB 30 K/RC units, independent of RLS 45 K settings.

System Operation Operating Mode

Describes system operation for PPB 30 K/RC units, synchronized with RLS 45 K or radio controls.

Operating Ventilation Unit(s)

Automatic Dehumidification

Information on automatic dehumidification strategies and its activation.

Exhaust Air Mode Configuration

How exhaust air mode is configured, including volumetric flow compensation.

Intensive Ventilation Configuration

Details on configuring intensive ventilation mode based on humidity levels.

Manual Exhaust Air Mode

Procedure for manual exhaust air mode on PPB 30 O units for full load air extraction.

Manual Exhaust Air Mode and Intensive Ventilation

How to activate manual exhaust air and intensive ventilation for PPB 30 K/RC units.

Operating Ventilation Unit(s)

Deactivating Ventilation Level "0"

How to deactivate ventilation level 0 (Off function) for continuous ventilation.

Control Unit's LED Display

Explanation of the LED display on control units and its configuration.

Sleep Mode with Ventilation Level 0

Details on the sleep mode functionality for specific ventilation units.

Intermittent Ventilation with Ventilation Level 5

Instructions for intermittent ventilation at level 5 for compatible ventilation units.

External OFF Function

Information on the external OFF function for switching off all ventilation system units.

Volumetric Flow Compensation in Supply Air Mode for Exhaust Air Units

Explanation of volumetric flow compensation for exhaust air units in supply air mode.

Radio-Controlled Operation (EnOcean)

Meaning of the LEDs

Explains the different LED indicators on the PP 45 RC / PPB 30 RC units and their meanings.

Radio Components Which Can Be Taught-In (EEP)

Overview of EnOcean radio components compatible with the EEP protocol for system integration.

Radio-Controlled Operation (EnOcean)

Radio Switch

Details on the DS 45 RC radio switch for operating PP 45 RC / PPB 30 RC units.

PP 45 EO EnOcean Extension Module

Information on the PP 45 EO module for enabling radio control with wired RLS 45 K.

Radio-Controlled Operation (EnOcean)

Radio Telegram Program Levels

Explains the different program levels for radio telegrams and their functions.

Teaching-In Radio Devices

Step-by-step guide for teaching-in various radio components like masters, slaves, and sensors.

Master-Slave Assignment

Instructions for assigning slave ventilation units to a PP 45 RC/PPB 30 RC master unit.

Teaching-In Radio Devices

Teaching-In Unit Pairs

Procedure for teaching-in ventilation unit pairs and radio switches/sensors to the master.

Teaching-In DS 45 RC Radio Switch

Steps for teaching-in the DS 45 RC radio switch to the master ventilation unit.

Teaching-In Radio Sensor

Guide for teaching-in radio sensors to the master unit via the TEACH button.

Teaching-In Radio Devices

Deleting Transmitters

Instructions for deleting previously taught-in radio transmitters from the master unit.

Setting the Ventilation Unit as a Signal Amplifier (Repeater)

How to configure the ventilation unit to act as a signal amplifier for EnOcean telegrams.

Teaching-In PP 45 ACT EnOcean Wireless Actuator

Steps for teaching-in the PP 45 ACT actuator for combining wired exhaust air units with RC units.

USB Connection (RLS 45 K)

ModBus Connection

Filter Changes, Unit Cleaning

Filter Change Indicator

Explanation of the LED indicators that signal when air filters need changing.

Replacement Filter, Ordering Filters

List of available replacement filters and where to order them from the Maico filter shop.

Changing Air Filters of PP 45 Units

Detailed steps for removing and inserting air filters in PP 45 ventilation units.

Filter Changes, Unit Cleaning

Cleaning PP 45 Ventilation Unit

Instructions for cleaning the internal grille, fan, and electronics cover of PP 45 units.

Changing Air Filters of PPB 30 Units

Steps for replacing air filters in PPB 30 units, triggered by the filter change indicator.

Filter Changes, Unit Cleaning

Cleaning PPB 30 Ventilation Unit

Guide for cleaning PPB 30 units, including internal components and external housing.

Faults, Rectification

RLS 45 O Fault Messages

List of fault messages for RLS 45 O units and their corresponding meanings.

Fault Messages of RLS 45 K

Details of fault messages for RLS 45 K units, including LED indications and error codes.

Faults, Rectification

PP 45 RC / PPB 30 RC Fault Messages

Explanation of fault messages for PP 45 RC/PPB 30 RC units, indicated by red LED flashes.

Technical Data

Technical Data for PP 45

Detailed technical specifications, including dimensions, airflow, and power for PP 45 units.

Technical Data for PPB 30

Detailed technical specifications, including dimensions, airflow, and power for PPB 30 units.

Decommissioning/Dismantling