12 Faults, rectification
67
12.3 PP 45 RC / PPB 30 RC fault mes-
sages
Red
LED (*)
Fault Display
Internal error in
control
Fault LED in alterna-
tion: lit up for exten-
ded period and then
flashes briefly 1x
Master-slave
communication
Fault LED in alterna-
tion: lit up for exten-
ded period and then
flashes briefly 2x
Internal sensor
defective (I2C)
Fault LED in alterna-
tion: lit up for exten-
ded period and then
flashes briefly 3x
External sensor
not reporting
Fault LED in alterna-
tion: lit up for exten-
ded period and then
flashes briefly 4x
No communica-
tion with the
EnOcean module
PP 45 EO
Fault LED in alterna-
tion: lit up for exten-
ded period and then
flashes briefly 5x
The faults are not acknowledged. Acknowledge-
ment takes place automatically when the fault is
remedied.