Panel controls, Inputs and Outputs
1. Clock Input. Advances sequence upon rising edge of clock, pulse or trigger signal of at least 2.0V
2. Clock Output. Output containing gates associated with Internal and/or External Clocks. 0V or 8V.
3. Dynamic Reset Input. Resets sequence to last touched Step upon rising edge of clock, pulse or trigger signal of at least
2.0V
4. Stop Input. Stops clock (internal and external) from advancing sequence for as long as input is >2.0V.
5. Direction Input. Changes/toggles sequence direction upon rising edge of clock, pulse or trigger signal of at least 2.0V.
6. Pitch Channel CV Output. Outputs CV at value of Pitch Channel knob for currently selected Step. 0-5V.
7. Strength Channel CV Output. Outputs CV at value of Strength Channel knob for currently selected Step. 0-5V.
8. Time Channel CV Output. Outputs CV at value of Time Channel knob for currently selected Step. 0-5V.
9. Pressure CV Output. Outputs CV according to amount of pressure applied to Step Touchplate(s). 0-5V.
10.Touch Gate Output. Outputs Gate signal when one or more Step Touchplate is being touched. 0V or 8V.
11.Dynamic Gate Output. Outputs Dynamic Gate Signal based on Strength and Time of current Step. 0-8V.
12.Dynamic Envelope Output. Outputs Dynamic Envelope based on Strength and Time of current Step. 0-8V.
13.Strength CV Input attenuator. Sets depth of Strength modulation from Strength Channel or signal at Strength CV Input.
14.Speed Panel Control. Sets Speed of Internal Clock and length of Dynamic Envelopes and Gates.
15.Strength CV Input. Modulates Strength of Dynamic Envelope and Gate outputs. Normalled to Strength Channel CV
Output.
16.Time CV Input Attenuator. Sets depth of Time modulation from Time Channel or signal at Time CV Input.
17.Time CV Input. Modulates Clock Time. Normalled to Time Channel CV Output.
18.Step Gate Outputs. Gate outputs that go high when respective Step is active. 0V or 8V.
19.Pitch Channel Knobs. Set Pitch Channel CV Output for the eight steps.
20.Strength Channel Knobs. Set Strength Channel CV Output for the eight steps.
21.Time Channel Knobs. Set Time Channel CV Output for the eight steps.
22.Step Touchplates. Clocks Sequence to respective Step (if Interrupt ON) and generate Pressure CV and Touch Gates.
23.Clock Touchplate. Turns Internal Clock On and Off.
24.Direction Touchplate. Changes/Toggles Direction of Sequence.
25.Interrupt Touchplate. Determines whether Step Touchplates will Interrupt the Sequence when touched.