2-32
25 - CONTROL SWITCH
NB: This control switch is progressive control, and gives a very high approach accurancy.
Its use should be smooth and free of jerkes.
SAFETY TRIGGER
This trigger (item A) of control control switch 25 must be
continually pushed in to perform movements from the operating
of the access platform.
26 - CONTACTOR OF SELECTION OF ROTATION
- This contactor (26) has three positions. Switch it over to the movements you desire and
then use the manipulator (25).
PLATFORM ROTATION
- Switch the contactor 26 to the left (position I).
- Incline to the right or to the left the control switch 25 to orientate on the right or on
the left respectively.
TURRET ROTATION
- Switch the contactor 26 to vertical (position II).
- Incline to the right or to teh left the control switch 25 to orientate on the right or on
the left respectively.
ROTATION OF ROTATED JIB 3D PLATFORMS
- Switch the contactor 26 to the right (position III).
- Incline to the right or to the left the contactor 25 in order to rotate on the right or on
the left respectively.
Before you make any rotation manoeuvres, check that there is
enough space betw
een the platform or the turret and the various
walls and installations.