3-22
D EVERY 200 HOURS OF OPERATION
D1 - OVERLOAD
CHECK
- The overload must activate at between 1.1 and 1.2 times the nominal load (see
CHAPTER 2 - General characteristics).
Expected result:
• Nominal load 200 Kg: activation load between 220 kg and 240 kg
- The overload sensors must activate at the same time.
Refer to the repair manual for information about adjusting the overload
D2 - STOPPING DISTANCE
CHECK
STOPPING DISTANCE ON HORIZONTAL GROUND:
- The stopping distance is tested on flat ground with 1.1 times the nominal load in the
basket.
- Reach maximum speed and then release the control.
Expected result:
On horizontal ground
Stopping distance
Transport speed 1000 mm +or- 200 mm
Working speed 70 mm +or- 30 mm
CHECK BRAKE HOLDING ON A SLOPE
- Place the nacelle on a nominal 25% slope static with 1.1 times the nominal load in the
basket.
Expected result: no slipping of the nacelle must be detected after one minute.
647536 (10/04/2017)