2-24
GROUND MAINTENANCE AND EMERGENCY STATION
1 - EMERGENY STOP
- This red mushroom-head switch cuts off all the machine’s movements in the event of
any anomalies or danger.
- Press the knob to stop the machine’s movements.
- Turn the knob a quarter of a turn to the right to restore the power (the switch
automatically returns to its initial position).
In all cases, this control takes priority, even when movements are
being controlled by the basket command and control station.
When the Emergency Stop is activated, the cessation of movements
can be very sudden.
Do not use the emergency stop to simply shut down the lifting
platform. Otherwise, rearm it immediately as no action can be
performed on the ground maintenance station and the basket
command station.
2 - KEY-OPERATED CONTROL SELECTOR SWITCH AT GROUND LEVEL OR IN THE BASKET
This 3-position BASKET / BASE control station, with the Stop position in the centre, powers the
basket control console when it is set in the PLATFORM position. When the selector is in the
BASE position, power to the console in the BASKET is cut off and only the base controls can be
used.
A : - Functions are controlled from the basket command and control station.
B : - Neutral position : the platform controls are idle (remove the key in this position)
C : - Functions are controlled from the ground backup and maintenance station.
3 - OVERLOAD LAMP
- If the basket is overloaded, the LED flashes intermittently (See : ACCESS PLATFORM
OPERATION– SAFETY INSTRUCTIONS ).
1
2
A
B
C
3
647536 (10/04/2017)
150 AETJ C / 170 AETJ L