Section 2 Installation References
2-7
J320/J420 Ice Machines
Air-Cooled Water-Cooled
Ice
Machine
Voltage,
Phase, Cycle
Maximum
Fuse/Circuit
Breaker
Minimum Circuit
Amps
Maximum
Fuse/Circuit
Breaker
Minimum Circuit
Amps
115/1/60 15 11.3 15 10.9
J320 208-230/1/60 15 4.8 15 4.2
230/1/50 15 4.6 15 4.0
115/1/60 20 12.7 20 11.8
J420 208-230/1/60 15 7.8 15 7.4
230/1/50 15 5.7 15 5.4
J200 - J1000 Ice Machines
Air-Cooled Water-Cooled Remote
Ice
Machine
Voltage,
Phase, Cycle
Maximum
Fuse/
Circuit
Breaker
Minimum
Circuit
Amps
Maximum
Fuse/
Circuit
Breaker
Minimum
Circuit
Amps
Maximum
Fuse/
Circuit
Breaker
Minimum
Circuit
Amps
115/1/60 15 10.5 15 10.0 N/A N/A
J200 208-230/1/60 15 5.4 15 4.8 N/A N/A
230/1/50 15 4.8 15 4.2 N/A N/A
115/1/60 20 12.7 20 11.8 20 13.7
J450 208-230/1/60 15 7.8 15 7.4 N/A N/A
230/1/50 15 5.7 15 5.4 N/A N/A
J600 208-230/1/60 15 7.4 15 6.9 15 8.2
230/1/50 15 6.4 15 6.1 15 6.5
208-230/1/60 20 11.8 20 11.1 20 12.1
J800 208-230/3/60 15 7.7 15 6.7 15 7.6
230/1/50 15 10.7 15 9.9 15 9.7
208-230/1/60 20 13.3 20 12.3 20 12.8
J1000 208-230/3/60 15 10.1 15 9.1 15 10.3
230/1/50 15 13.6 15 12.1 15 12.9
208-230/1/60 30 19.0 30 17.4 30 18.4
J1300 208-230/3/60 20 12.9 20 11.3 20 10.6
230/1/50 30 19.9 30 18.7 30 18.1
380-415/3/50 N/A N/A N/A N/A 15 7.3
208-230/1/60 35 23.8 35 22.2 35 22.3
J1800 208-230/3/60 20 17.0 20 15.4 20 15.1
230/1/50 35 23.0 35 21.5 35 20.6
380-415/3/50 N/A N/A N/A N/A 15 9.1