EasyManuals Logo

Manitowoc J250 User Manual

Manitowoc J250
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Section 6Electrical System
6-32
NEW STYLE REMOTE - J450/J600/J800/J1000 - 1 PHASE
SV1582
L1
TB35
TB30
TB30
TB30
TB30
SEE SERIAL PLATE FOR VOLTAGE
L2 (N)
CAUTION: DISCONNECT POWER BEFORE
WORKING ON ELECTRICAL CIRCUITRY.
NOTE:
DIAGRAM SHOWN DURING FREEZE CYCLE.
TB32 (55)
(61)
(60)
(77)
(76)
(80)
(75)
(98)
(57)
(99)
(81)
(58)
(59)
(73)
(56)
(74)
TB31
TB37
3
1
2
4
TRANS.
FUSE (7A)
1C
1F
HIGH
PRESSUR
E CUT-
OUT
ICE THICKNESS PROBE
LOW D.C.
VOLTAGE
PLUG
CONNECTION NOT USED
BIN SWITCH
(62)
(63)
(64)
(65)
(66)
(66)
(67)
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
BIN SWITCH LIGHT
(
68
)
(
69
)
(62)
V
IEW FOR WIRING
66
67
68
69
62
TOGGLE SWITCH
CLEAN
OFF
ICE
INTERNAL
WORKING VIE
W
HOT GAS
SOLENOID
DUMP
SOLENOID
WATER
PUMP
CONTACTOR
COIL
HPR
SOLENOID
(79)(78)
(83) (82)
LIQUID LINE
SOLENOID
(
49
)
(
47
)
COMPRESSOR
TB35
TB30
TB30
*OVERLOAD
CONTACTOR
CONTACTS
(
48
)
(
42
)
(
51
)
(
52
)
(
53
)
TB33
TB34
SR
C
(
50
)
PTCR
L1
(
46
)
RUN CAPACITOR
RR
(
45
)
TERMINATES AT
PIN CONNECTION
(
F1
)
(
F2
)
REMOTE
FAN MOTOR
RUN CAPACITOR
REMOTE
CONDENSER
LIGHT NOT USED
CLEAN LIGHT