T1 & T3 TEMPERATURE/RESISTANCE CHART
Important
If the ohmmeter reads “OL,” check the scale setting on
the meter before assuming the thermistor is bad.
Temperature Resistance Temperature Resistance

K Ohms


K Ohms

-50 344.6 26 4.771
-49 320.5 27 4.567
-48 298.2 28 4.375
-47 277.6 29 4.190
-46 258.7 30 4.016
-45 241.1 31 3.849
-44 224.8 32 3.690
-43 209.8 33 3.538
-42 195.9 34 3.394
-41 183.0 35 3.256
-40 171.0 36 3.124
-39 159.9 37 2.999
-38 149.5 38 2.879
-37 140.0 39 2.764
-36 131.1 40 2.656
-35 122.8 41 2.551
-34 115.1 42 2.452
-33 108.0 43 2.356
-32 101.2 44 2.266
-31 95.03 45 2.179
-30 89.24 46 2.095
-29 83.83 47 2.016
-28 78.79 48 1.940
-27 74.09 49 1.867