Installation manual I Manusa
D01230EN-v4
152. Commissioning
Workflow:
Menu 4: Hold-open time
4
4.1 Hold-open time [0-9]
Menu 5: Delayed close
5
5.1 Closing [0-9]
Menu 6: Management
6
6.1 Door pairing mode
Allows you to control the amount of time that the door is held open.
The value range is from 0 to 9, whereby 0 = 0 s and 9 = 9.9 s.
By default, a *0 hold-open time is defined.
The digits [x - y] are shown on the screen.
x = menu and y = the value of the hold-open time (flashing).
*Hold-open time
Min..
Hold-open time
Max.
Allows to control the closing time of the door.
The value range is from 0 to 9, whereby 0 = 0 s and 9 = 99.9 s.
By default, timing 0 is defined.
The digits [x - y] are shown on the screen;
x = menu and “y” = blinking timed shutdown value.
*Delayed close
Min.
Delayed close
Max.
This menu enables the link between the door and the command.
Place door in pairing mode. Menu 6.1:
Pairing starts when you press OK once. At this point, the LED sequence
starts.
The program switch sends a frame to the door (server) to place it into pairing
mode until a command is found; if no command is found, it exits this state
aer a few seconds. The door is inoperable until it finds a command.
The display shows the door “SETUP” icon and a wave sequence moving
outwards:
The wall program switch shows this until the pairing mode is exited.