ELECTRICAL
CONNECTIONS,
GROUNDING
AND
BONDING
All
a/c
units
have
a
terminal
strip
mounted
inside
the
electric
box.
The
terminal
strip
is
labeled
for
proper
connections
of
the
electrical
supply,
ground
wires
and
pump
circuits.
A
wiring
diagram
is
provided
in
the
electrical
box
and
in
this
manual.
The
correct
size
circuit
breaker
should
be
used
to
protect
the
system
as
specified
on
the
a/c
unit's
data
plate
label.
A
minimum
of
12
AWG
boat
cable
should
be
used
to
supply
power
to
the
a/c
unit
and
the
seawater
pump.
All
connections
shall
be
made
with
ring
or
fork
terminals.
Turn
off
a/c
power
supply
circuit
breaker
before
opening
electric
box.
Each
a/c
unit
installed
requires
its
own
dedicated
circuit
breaker.
If
there
is
only
one
a/c
unit
installed,
the
seawater
pump
does
not
require
a
circuit
breaker;
the
wiring
from
the
seawater
pump
is
connected
to
the
terminal
strip
in
the
electric
box.
If
two
or
more
a/c
units
use
the
same
seawater
pump,
the
pump
wires
will
be
connected
to
a
pump
relay
panel
(PRP)
which
in
turn
has
its
own
dedicated
circuit
breaker
sized
for
the
pump
(20
amp
max).
Please
see
the
wiring
diagram
furnished
with
the
PRP
(NOTE:
PRP
triac
must
have
its
mounting
screw
installed
in
order
to
dissipate
heat).
Electrical
connections
in
the
bilge
and/or
below
the
waterline
should
use
heat
shrink
type
butt
splices.
Field
wiring
must
comply
with
ABYC
electrical
codes.
Power
to
the
unit
must
be
within
the
operating
voltage
range
indicated
on
the
data
plate.
Properly
sized
fuses
or
HACR
circuit
breakers
must
be
installed
for
branch
circuit
protection.
See
data
plate
for
maximum
fuse/circuit
breaker
size
(mfs)
and
minimum
circuit
ampacity
(mca).
All
units
must
be
effectively
grounded
to
minimize
the
hazard
of
electrical
shock
and
personal
injury.
The
following
are
to
be
observed:
1.
AC
(alternating
current)
grounding
(green
wire)
must
be
provided with
the
AC
power
conductors
and
connected
to
the
ground
terminal
(marked
"GRND")
at
the
AC
power
input
terminal
block
of
the
unit(s),
per
ABYC
standard
E-8,
or
equivalent.
2.
Connections
between
the
vessel's
AC
system
grounding
conductor
(green
wire)
and
the
vessel's
DC
(Direct
Current)
negative
or
bonding
system
should
be
made
as
part
of
the
vessel's
wiring,
per
ABYC
standard
E-9,
or
equivalent.
3.
When
servicing
or
replacing
existing
equipment
that
contains
a
chassis-mounted
ground
stud,
the
service
person
or
installer
must
check
the
vessel's
wiring
for
the
existence
of
the
connection
required
in
item
2
above.
ABYC
standards
are
available
from:
American
Boat
and
Yacht
Council
3069
Solomon's
Island
Rd.
Edgewater,
MD
21036
Telephone:
(410)
956-1050
The
a/c
unit
must
be
connected
to
the
ship's
bonding
system
to
prevent
corrosion
due
to
stray
electrical
current
or
voltage.
All
pumps,
metallic
valves
and
fittings
in
the
seawater
circuit
that
are
isolated
from
the
a/c
unit
by
PVC
or
rubber
hoses
must
be
individually
bonded
to
the
vessels
bonding
system
also.
This
will
help
eliminate
any
possibility
of
corrosion
due
to
stray
current
or
voltage.
FAILURE
TO
PROPERLY
GROUND
AND
BOND
THE
SYSTEM
WILL
VOID
WARRANTY!
3
PHASE
NOTICE
It
is
extremely
important
to
insure
that
wiring
and
phase
sequencing
of
a
three
phase
power
source
is
correct.
Marine
wiring
standards
call
for
power
source
phases
LI,
L2,
and
L3
to
be
color-coded
BLACK,
WHITE,
and
RED,
respectively.
These
must
be
connected
to
the
unit
with
the
proper
sequence,
otherwise,
it
will
not
operate
properly.
If
the
wiring
sequence
is
incorrect,
the
unit's
compressor
{Scroll
type
only)
and
pump
(if
applicable)
will
run
in
the
reverse
direction
at
a
significantly
increased
noise
level.