UNPACKING
AND
INSPECTION
When
the
equipment
is
received,
all
items
should
be
carefully
checked
against
the
packing
list
to
ensure
all
cartons
have been
received.
Move
units in
the
normal
"up"
orientation
as
indicated
by
the
arrows
on
each
carton.
Examine
cartons
for
shipping
damage,
removing
the
units
from
the
cartons
if
necessary.
If
the
unit
is
damaged,
the
carrier
should
make
the
proper
notation
on
the
delivery
receipt
acknowledging
the
damage.
SAFETY
CONSIDERATIONS
VERY
IMPORTANT:
A/ever
install
your
air
conditioner
in
the
bilge
or
engine
room
areas.
Insure
that
the
selected
location
is
sealed
from
direct
access
to
bilge
and/or
engine
room
vapors.
Do
not
terminate
condensate
drain
line
within
four
(4)
feet
of
any
outlet
of
engine
or
generator
exhaust
systems,
nor
in
a
compartment
housing
an
engine or
generator,
nor
in
a
bilge,
unless
the
drain
is
connected
properly
to
a
sealed
condensate
or
shower
sump
pump.
Installation
and
servicing
of
this
system
can
be
hazardous
due
to
system
pressure
and
electrical
components.
When
working
on
this
equipment,
always
observe
precautions
described
in
the
literature,
tags
and
labels
attached
to
the
unit.
Follow
all
safety
codes.
Wear
safety
glasses
and
work
gloves
and
place
a
fire
extinguisher
close
to
the
work
area.
The
following
is
a
summary
of
the
labels
on
the
unit:
!
DANGER
ELECTRICAL
SHOCK
HAZARD.
DISCONNECT
VOLTAGE
AT
MAIN
PANEL
OR
POWER
SOURCE
BEFORE
OPENING
ANY
COVER.
FAILURE
TO
COMPLY
MAY
RESULT
IN
INJURY
OR
DEATH.
!
WARNING
THIS
COMPONENT
DOES
NOT
MEET
FEDERAL
REQUIREMENTS FOR
IGNITION
PROTECTION.
DO
NOT
INSTALL
IN
SPACES
CONTAINING
GASOLINE
ENGINES,
TANKS,
LPG/CPG
CYLINDERS,
REGULATORS,
VALVES
OR
FUEL
LINE
FITTINGS.
FAILURE
TO
COMPLY
MAY
RESULT
IN
INJURY
OR
DEATH
NOTICE
THIS
COMPONENT
IS
CHARGED
WITH
HYDROCHLOROFLUOROCARBON
(HCFC)
REFRIGERANT
R22.
EFFECTIVE
JULY
1,
1992
IT
SHALL
BE
UNLAWFUL
FOR
ANY
PERSON
TO
KNOWINGLY
VENT
OR
OTHERWISE
KNOWINGLY
RELEASE
ANY
CLASS
1
(CFC)
OR
CLASS
2
(HCFC)
SUBSTANCE
AS
A
REFRIGERANT
IN
A
MANNER
WHICH
PERMITS
SUCH
SUBSTANCE
TO
ENTER
THE
ATMOSPHERE
PER
THE
CLEAN
AIR
ACT
OF
1990.
PUBLIC
LAW
101-549
TITLE
IV
SECTION
608-C.
FAILURE
TO
COMPLY
MAY
RESULT
IN
SEVERE
PENALTIES,
INCLUDING
FINES
AND
IMPRISONMENT.
!
WARNING
TO
MINIMIZE
THE HAZARD
OF
ELECTRICAL
SHOCK
AND
PERSONAL
INJURY,
THIS
COMPONENT
MUST
BE
EFFECTIVELY
GROUNDED.
REFER
TO
THE
INSTALLATION
GUIDELINES
FOR
FURTHER
INFORMATION.
CAUTION!
HIGH
COMPRESSOR
TEMPERATURE
IS
NORMAL
DO
NOT
TOUCH