7
SAFETY HOSE AND REGULATOR
REGULATOR FLOW LIMITING DEVICE
If you are experiencing any of the following performance issues you may have activated the flow limiting feature in
your regulator:
• Burners not getting hot enough
• Low or incomplete burner flames
• Low gas pressure
• Burners not staying lit
RESETTING THE REGULATOR FLOW LIMITING FEATURE
1. With all control knobs and the gas source in the OFF/“0” position.
2. Disconnect the regulator from the LP cylinder.
3. Turn all control knobs to the MAX/“05” position, and let stand for 1-3 minutes, allowing all excess gas in the
gas manifold to dissipate.
4. Turn all control knobs to the OFF/“0” position.
5. Reconnect the hose and regulator to the LP cylinder—do not cross thread the connection. Hand-tighten only.
6. Check all hose connections to ensure that a positive seal has been made.
7. Slowly open the LP cylinder shut-o valve.
NOTE: If the LP cylinder is opened too quickly, the flow limiting device in the regulator will activate, limiting
the flow of gas from the LP cylinder
8. Wait approximately 5 seconds for the hose and regulator pressure to stabilize (to prevent the flow limiting
device feature from being re-activated).
9. Start with the middle two control knobs. To ignite, push and turn the ignition burner knob ( )to MAX/“05”
position. You will hear a “click” sound as the piezo starter is activated in the control knob. Confirm that the
burner is lit before continuing.
10. Repeat step 9 for all remaining burners.
CAUTION: Avoid activating the flow limiting feature by following the proper start up and shut down
procedures and performing a complete leak test and safety check to ensure that there are no leaks in the
system and that a positive connection has been made between the gas source and manifold assembly.