TelnetandSSHDefaults
Firmwareversion4.5.0
DISPLAY:
Brightness=12outof15
Dateformat=MM/DD/YY
Timeformat=24hour,Local
Leadingzeros=OFF
DayofYear=OFF
Dashesenabled,appearafterdeviceisunlockedfor86400seconds
NETWORKCONFIGURATION:
DHCP=on
IPV4address,IPV6address,Netmask,GatewayandDNS
setbyDHCPserver.
COMMUNICATIONSCONTROL:
Telnet:
Telnet=OFF
SNMP:
Agentstate=RUNNING
Contact=BLANK
Location=BLANK
Name=BLANK
Community2=BLANK
CurrentCommunity=0
TrapReceivers0through5=BLANK
INPUTCONTROL:
NTPClient:
State=NOTENABLED
Query
NTPServerForTime=ON
ListenForNTPviaBroadcastAddress=OFF
ListenForNTPviaMulticastAddress=OFF
UseNTPserverprovidedbytheDHCPserver=OFF
PrimaryNTPserver=BLANK
SecondaryNTPserver=OFF
IgnoreNTPresponsewhenthealarm
flagisset=OFF
MicrosecondOffset=0
TimeCodeReader:
SMPTE:
Ignoredateonincomingtimecode=OFF
DateusesLeitchdateencodingformat=ON
DateusesSMPTE309Mencoding.=OFF
DateusesSMPTE309Mencoding.=OFF
IRIGTimeCodeSettings:
Ignore
DayofYearandYearonincomingtimecode.=OFF
IncomingTimeCodeReference:
UTC=OFF
Local=OFF
Custom=OFF