12/75-3, 12/100-3, 24/40-3, 24/60-3 – User and Installation Manual
4.2.7 History
This menu shows the absolute maximum readings.
Value Meaning Value range
Charger
Days running Total run time in charger mode (read only)
Highest voltage Highest detected DC voltage output 1 (read only)
Lowest voltage Lowest detected DC voltage output 1 (read only)
Total Ah’s Total charged Ah’s (read only)
Output 2
Highest voltage Highest detected DC voltage output 2 (read only)
Lowest voltage Lowest detected DC voltage output 2 (read only)
Total Ah’s Total charged Ah’s (read only)
Highest voltage Highest detected DC voltage Smart terminal (read only)
Lowest voltage Lowest detected DC voltage Smart terminal (read only)
Total Ah’s Total charged Ah’s (read only)
Total Ah’s in Total charged Ah’s using the smart terminal as input (read only)
4.2.8 Configuration
Below parameters can be changed via the MasterBus network by means of a remote control panel or by means of an interface
connected to a PC with MasterAdjust software. See applicable user manuals for details.
Value Meaning Factory setting Value range
Menu language of this device
EN, NL, DE, FR, ES, IT, NO, SV, FI, DA
Name of this device. This name will be
recognized by all devices connected to the
ChargeMaster
Select if MasterBus communication is
available when only DC power is available.
3-Step+, constant voltage
Maximum DC output current
Depending on model 20-100%
User defined, AGM, GEL, Flooded, AGM
Spiral, Flooded traction, Flooded calcium,
compensate
Temperature depended charge voltage
compensation
Smart terminal operation mode
Starter, Starter+alternator, Follow main,
Follow main+alternator, 12V constant
voltage, 24V constant voltage*, 12V 3-
Smart terminal maximum DC output current
Voltage threshold used to switch over when
Smart Terminal acts as VSR
Smart terminal maximum DC input current
Bulk voltage (@ 25°C); see section 5.4
Minimum time of the Bulk phase since
Start
Start time at
Battery voltage trigger point to start the bulk
timer
13.25/26.50V (read only)