12/75-3, 12/100-3, 24/40-3, 24/60-3 – User and Installation Manual
not overfill. For a battery without removable cell caps,
such as valve regulated lead acid batteries, carefully
follow manufacturer’s recharging instructions.
5 Study all battery manufacturer’s specific precautions
while charging and recommended rates of charge.
Note that the ChargeMaster Plus charge
specifications are based on Mastervolt batteries.
Specifications for a given chemistry of a different
manufacturer may vary. If connecting batteries of a
different manufacturer, make sure the manufacturer's
recommendations are met.
6 Determine voltage of battery by referring to car
owner’s manual and make sure that output voltage
selector switch is set at correct voltage. If charger has
adjustable charge rate, charge battery initially at
lowest rate. Exception: For a charger not having an
output voltage selector switch, determine voltage of
battery by referring to car owner’s manual and make
sure it matches output rating of battery charger.
2.10 Grounding instructions
This battery charger should be connected to a grounded,
metal, permanent wiring system; or an equipment-
grounding conductor should be run with circuit conductors
and connected to equipment-grounding terminal or lead on
battery charger. Connections to battery charger should
comply with all local codes and ordinances.
2.11 Warning regarding life support
applications
Mastervolt products are not designed to be used as
component of medical equipment, unless negotiated in the
form of a written agreement between customer and/or
manufacturer and Mastervolt. Such agreement will require
the equipment manufacturer either to contract additional
reliability testing of the Mastervolt parts and/or to commit
to undertake such testing as a part of the manufacturing
process. Furthermore, the manufacturer must agree to
indemnify and not hold Mastervolt responsible for any
claims arising from the use of the Mastervolt parts in the
life support equipment.