EasyManua.ls Logo

Matrix A7XI-01 - Troubleshooting - Error 0148

Matrix A7XI-01
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67
8.9 TROUBLESHOOTING - ERROR 0148
CHAPTER 8: TROUBLESHOOTING
ERROR CODE 0148
1) SYMPTOM:
0148 – Incline motor over current.
2) SOLUTION:
1) Follow the instructions in Section 3.5 to run Auto Calibration (Figure B).
2) Disconnect the incline tube from the incline frame (Figure A), then turn on the power.
- If the console still shows 0148, replace the incline motor.
- If the console does not show 0148, follow the incline motor installation procedure in Section 9.13 to re-attach the incline motor.
3) Replace the LCB.
FIGURE A FIGURE B

Table of Contents