EasyManua.ls Logo

Matrix A7XI-01 - Troubleshooting - Error 0149

Matrix A7XI-01
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68
8.10 TROUBLESHOOTING - ERROR 0149
CHAPTER 8: TROUBLESHOOTING
FIGURE A
ERROR CODE 0149
1) SYMPTOM:
0149 – The resistance current is over 3.7A for 1 second.
2) SOLUTION:
1) Check if the resistance is short circuited by measuring amperage through the power resistance cable (Figure A).
- If the resistance value is under 10 ohms, replace the power resistance.
- If the resistance value is over 10 ohms, replace the LCB.