32
[Symptom]
Press start then the console display show “Error 3 or 6“
[Cause]
1. The 20-pin console cable is damaged.
2. Incline motor is damaged.
3. PCB is damaged.
4. Incline power board is damaged.
5. The incline setting is not correct.
[Solution]
1.Enter the “Engineer mode” select P4:LOW ELEVATION console display will
show incline motor parameter (Please refer the below photo), if display not show
right parameter, please check the between Incline power board and incline motor
whether connect is OK, if it is OK, please replace new console cable to test again.
2. If display still show “Error 3 or 6“, please replace the incline motor.
3. If display still show “Error 3 or 6“, please replace the PCB.
4. If display still show “Error 3 or 6“, please replace the incline power board.
5. Enter Engineering Mode to Auto-calibration place to renew the Auto-
calibration elevation parameter (Please refer the page 22) .
Error message 3,6 troubleshooting
Incline motor right
now place parameter
Incline motor Default
Value place parameter