Chapter 6 Maintenance
- 47 -
Maintenance item Description
Filter cleaning
Dry filter)
Removing a filter case of dehumidifying unit , check and clean up the
filter clogging as shown in Figure53.
Catchclips
Dry filter
picture 53
(Regeneration filter)
In case of DMS2-120,170,240
Removing a filter stopper in the dehumidifying unit, check and clean
up the regeneration filter clogging as shown in Figure54.
use the fingers to clinch
the part and conduct
installation and dismantle.
Regeneration filter
Filter stopper
Picture 54
Cleaning of cooling water line
Clean the strainer of cooling water line of the equipment at your
company. If cooling water does not run because of dust etc., drying
dew point will not go down and this may cause inadequate drying.
CAUTION
Strainer is not fitted to this equipment.