Chapter 8 Troubleshooting
- 55 -
The air quantity from the blower is small.
Check point Action Remarks
Take the cartridge filter out
of the line filter case, and
check it for clogging.
If it is dirty or clogged, blow
clean dry air on the inside of
the cartridge filter to remove
adherents.
If deterioration of the cartridge
filter is too great to remove
adherents, replace it with a
new cartridge filter.
For purchase and type of the
cartridge filter, contact your
nearest MATSUI BRANCH or
distributor.
Dismount the regeneration
filter, and check the filter for
clogging.
If it is dirty or clogged, blow
clean dry air on the inside of
the cartridge filter to remove
adherents.
If deterioration of the cartridge
filter is too great to remove
adherents, replace it with a
new cartridge filter.
For purchase and type of the
cartridge filter, contact your
nearest MATSUI BRANCH or
distributor.
Check the connection hoses
in the dehumidifying unit and
the hose connecting the
dehumidifying unit, the
drying hopper for breakage
and check the connections
for looseness.
If any hose is broken, replace it
with a new hose.
If any hose connection is
loose, securely tighten the
hose band.
If any air leak is found, stop the
system and work after waiting
until the heating parts cool
down sufficiently.
The change of the dry temperature is large.
Check point Action Remarks
Take the cartridge filter out of
the line filter case, and check
it for clogging.
If it is dirty or clogged, blow
clean dry air on the inside of
the cartridge filter to remove
adherents.
If deterioration of the cartridge
filter is too great to remove
adherents, replace it with a
new cartridge filter.
Dismount the regeneration
filter, and check the filter for
clogging.
If it is dirty or clogged, blow
clean dry air on the inside of
the cartridge filter to remove
adherents.
If deterioration of the cartridge
filter is too great to remove
adherents, replace it with a
new cartridge filter.