Chapter 8 Troubleshooting
- 58 -
The moisture content of resin does not decrease.
Check point Action Remarks
Check the cooling water flow
and water volume lack.
When cooling water isn't
flowing, confirm the open
condition of each valve.
Take the cartridge filter out of
the line filter case, and check it
for clogging.
If it is dirty or clogged, blow
clean dry air on the inside of
the cartridge filter to remove
adherents.
If deterioration of the cartridge
filter is too great to remove
adherents, replace it with a
new cartridge filter.
Dismount the regeneration
filter, and check the filter for
clogging.
If it is dirty or clogged, blow
clean dry air on the inside of
the cartridge filter to remove
adherents.
If deterioration of the cartridge
filter is too great to remove
adherents, replace it with a new
cartridge filter.
Check the connection hoses in
the dehumidifying unit and the
hose connecting the
dehumidifying unit, the drying
hopper for breakage and check
the connections for looseness.
If any hose is broken, replace it
with a new hose.
If any hose connection is
loose, securely tighten the
hose band.
If any air leak is found, stop the
system and work after waiting
until the heating parts cool
down sufficiently.