EasyManua.ls Logo

Matsui DMS2-80 - Page 64

Matsui DMS2-80
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Troubleshooting
- 60 -
The thermal setting value of every model (A)
OCR-1
Setting current(A)
Power Type
50Hz 60Hz
DMS2-80
4.34.8 54.54
DMS2-120
4.34.8 54.54
DMS2-170
7.448.76 8.27.3
DMS2-240
10.810.9 11.710.3
DMZ2-40
1.722.41 1.931.93
DMZ2-80
4.34.8 54.54
AC200V
AC220V
DMZ2-120
7.448.76 8.27.3
DMS2-80
2.533.25 2.632.53
DMS2-120
2.533.25 2.632.53
DMS2-170
4.366 4.384.27
DMS2-240
5.86.7 6.46
DMZ2-40
1.11.56 1.181.08
DMZ2-80
2.533.25 2.632.53
AC380
AC440V
DMZ2-120
4.366 4.384.27