Chapter 11 Specifications
- 67 -
Type DMZ2- 40 80 120
Control
Drying temperature
adjustment
PID control
Regeneration temperature
adjustment
PID control
Out automatic start timer
Set up times (10minute~99hour50minute)
Over-temperature (drying regeneration)
Motor over-load
Running prevention
Alarm protection loop
Cooling delay when stopping
Power supply AC200V 50/60Hz,220V 60Hz,380V 50/60Hz,415V
50/60Hz 3P
Operation circuit voltage
50/60Hz
AC200/220V, 1 P
200V~220V
20(20) 32(40) 40(50)
Capacity of
power
breaker (A)
380V~415V
10(16) 16(20) 20(32)
Weekly timer
Electricity leakage breaker
Dew point indicator
Upper limit of drying temperature alarm
Different voltage
Compatible
option
Transport control
W mm 440 500
D mm 570 704
Outer
dimensions
H mm
1410
Weight kg
120 160 200
Capacitance
(Max)
KVA
5.53(6.13) 8.59(10.19) 11.88(14.58)