55
PARAMETERS
www.maxcessintl.com
MI 850A348 1 E
Miscellaneous
Parameter #
Description
Default
P.19
Tension number format
Tells whether tension display is 3-digit with no fixed right-hand
zero or 3-digit with fixed right-hand zero.
0
0 =
Auto Select between formats. (Based on value in
Maximum Tension C1.3 or C2.5).
1 =
3-digit with no fixed right-hand zero.
2 =
3-digit with fixed right-hand zero.
P.20
Tension polarity
Set to -1 to show positive tension when the force is acting in
the direction opposite the force direction arrow on the load
cells. Set automatically by Precision calibration.
+1
P.21
DP position
Set the decimal point position to show when displaying tension
0
0 =
0000
1 =
0000.
2 =
000.0
3 =
00.00
4 =
0.000
P.22
Lock out zeroing tension from [] button and digital input when
a password has locked the DLCA.
0
0 =
Zeroing tension allowed when password has locked the
DLCA
1 =
Zeroing tension locked out when password has locked
the DLCA
P.23
Firmware Version. Displays the firmware version.
P.24
Exit from menu and return to displaying tension