81
SPECIFICATIONS
www.maxcessintl.com
MI 850A348 1 E
General
Supply voltage range
24 VDC +/-10%
Proper earth grounding is required.
Note that the negative supply and earth
ground are interconnected.
The power supply must have an SELV output,
such as Puls ML15.241, Mean Well MDR-20-
24 or equivalent
The Mean Well MDR-20-24 can be purchased
from Fife as part number 93157-024.
Supply current
0.14 A, max.
Internal fuse
2.5 A, fast-blow
Bussman GBD2.50, or Littelfuse 21702.5
Temperature range
Operating
Storage
-
-
0° to 50°C (32° to 122°F)
-20° to 80°C (-4° to 176°F)
Enclosure
-
IP20
Climatic class
-
3K3 (EN60721)
Relative humidity
-
5% to 85%
Pollution degree
-
2 (IEC664-1)
Dimensions
Height - 58.9 mm (2.32 in),
Length 70.0 mm (2.76 in)
Width 86.0 mm (3.39 in)
Display
-
4-digit LED, 3-digit tension resolution.
Display decimal point
-
selectable position.
Maximum gain
-
32:1
Tare Adjustment
-
90% of Load Cell Rating.