11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
20
STEP 8 - REMOVE LOCKING ANGLES & WELDS
1. Push Control Switch to RAISE position to pressurize Hydraulic System. Listen for
Hydraulic Fluid flowing through the system. Check for fluid leaks. (If there are leaks, release
the Control Switch and correct the leaks before fully pressurizing system.) When the sound
of flowing fluid stops, release Control Switch. Hydraulic System is ready.
2. Remove Locking Angles from Hydraulic Cylinders (FIG. 20-1A).
NOTE: To operate Liftgate, Locking Angles must be removed from the Hydraulic Cylin-
ders and welds must be removed from Lifting Arm Knuckles.
3. With Platform open (FIG. 20-1A), grind off each weld as shown in FIG. 20-1B & 20-1C.
Make sure block remains on correct side of each Knuckle Joint as shown in FIG. 20-1D &
20-1E.
FIG. 20-1A
BLOCK STAYS
HERE
FIG. 20-1B
FIG. 20-1C
FIG. 20-1D
FIG. 20-1E
CUT WELD
HERE
FLIPOVER
(UNFOLDED)
PLATFORM
(UNFOLDED)
LOCKING
ANGLE
BLOCK STAYS
HERE
CUT WELD
HERE