11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
23
1” LG.
4 PLACES
3/16”
6. Stow and unfold Liftgate several
times to verify there is no interfer-
ence. If there is no interference,
weld Opener to Main Frame
(FIG. 23-1).
OPENER
MAIN
FRAME
WELDING OPENER TO MAIN FRAME
FIG. 23-1
STEP 9 - WELD PLATFORM OPENER TO LIFTGATE
- Continued
If there is any interference with the Platform while stowing Liftgate, check for dam-
age on bottom of Platform, Flip Over, and the hinge in between. A damaged Platform
or Flip Over may result in personal injury and more damage to Liftgate.
CAUTION
!
7. If the Platform lowered with a “jerk-
ing” motion, bleed air from the
Hydraulic System by doing the
following. Push the Control Switch to
the LOWER position until you hear
air escaping into the Hydraulic Fluid
Reservoir. RAISE the Platform and
then repeat this step until there is no
air left in the system and Platform
lowers smoothly.