Intelimax+4G User Manual
- 53 -
System Functions
Save Config to file
Save modem configuration as an encrypted .dat file.
Load Config from file
Load modem .dat configuration file.
Save syslog
If remote syslog is not enabled, this will print out the internal system logs to the ‘Output
Info’ window. Depending on the size of the internal syslog file, this may take several
minutes. Once this is completed a ‘LogFile’ will be saved in the same location as the GUI
.exe or it can be saved using the ‘Output Info’, ‘Save Output’ button.
Save signal
This will output the profile of signal strength from the modem over the previous 90 day
period to a signals.log file and to the ‘Output Info’ screen. The output file has the
following per-line format: “[Sun Jan 2 14:19:09 UTC 2000],69,69,70”, where the final three
numbers are average, min, and maximum signal strength over the preset period.
Set Profile
Sets the modem profile, which is also recovered by holding down the reset button for
between 5 and 20 seconds. The modem can therefore have 3 different configurations,
the current running configuration, which is saved to the modem with the ‘Save Config to
Modem’ button, the profile configuration, which is saved using the ‘Set profile’ button,
and the factory settings.
Load Profile
Recovers the modem profile. Is also achieved by holding down the modem reset button
for between 5 and 20 seconds.
Factory
Resets the Intelimax+ to firmware factory settings. This will wipe all the settings on the