Intelimax+4G User Manual
- 56 -
SMS Commands
Commands in IP modes
The Intelimax+ can be used to send and receive SMS messages through standard SMS AT
commands with an internal buffer of 100 messages. In addition to this the Intelimax+
supports a number of custom SMS messages for which can be used to check and modify
some settings remotely.
There are a number of symbols that are not interpreted correctly through the cellular
module. When configuring a username or password the modem will correctly interpret
the special character but the response may not match. For example the ‘@’ symbol will
be interpreted correctly, but the response may show a ‘¡’ symbol as the response even
though the ‘@’ symbol has been correctly received by the modem.
Following SMS commands can be used to change the APN, ID, Password, Authentication
and even rebooting Intelimax+. Also after changing the APN, ID, Password,
Authentication, Intelimax+ will send a confirmation SMS after applying the change.
Change APN (e.g. telstra.extranet)
SMS Syntax: INTELIMAX.PARK.APN telstra.extranet
Change Username, Password and Authentication (e.g. Username:
maxon@maxon.com.au, Password: maxon, Authentication: chap)
SMS Syntax: INTELIMAX.PARK.AUTH maxon@maxon.com.au:maxon:chap
Note: Please see above regarding special characters such as ‘@’.
Check Settings and IP address
SMS Syntax: INTELIMAX.PARK.WANIP
Reboot Intelimax+
SMS Syntax: INTELIMAX.PARK.REBOOT
RSSI Info
SMS Syntax: INTELIMAX.PARK.RSSI
DDNS configuration change by SMS
SMS Syntax:
INTELIMAX.PARK.DDNS1 <mode 1-enable 0-disable>(,<host address>)
e.g. INTELIMAX.PARK.DDNS1 1,dyn.com