TROUBLESHOOTING
P
LATFORM WILL NOT LOWER, LOWERS TOO SLOWLY, OR TOO QUICKLY
1. Connect voltmeter (+) lead to 
motor solenoid terminal “B” and 
the (-) lead to the ground wires 
connection on pump (FIG. 34-1). 
Verify that full battery voltage 
is at “B”. Recharge the battery 
if voltmeter indicates less than 
12.6 volts dc.
2. Check for structural damage or 
poor lubrication. Replace worn 
parts.
TERMINAL “B” 
BATTER
Y (+)
TERMINAL “D”
COIL DRIVE
TERMINAL “C”
GROUND (-)
POWER UNIT
FIG. 34-1
TERMINAL “A”
LOAD
VALVE “C”
LOWERING 
SOLENOID V
ALVE
STARTER
SOLENOID
3. Check if the “D” terminal and 
“A”
 (lowering) solenoid valve 
are getting battery voltage (FIG. 
34-1). Connect voltmeter nega-
tive (-) lead to ground (-) wires 
connection on pump and posi-
tive (+) lead to the “D” terminal 
(FIG. 34-1). Hold control switch 
in the “LOWER” position. Then, 
connect voltmeter (+) lead to 
(+) terminal on the “A” (lower-
ing) solenoid valve (FIG. 34-1). 
If voltmeter shows a much lower 
reading than +12.6 volts dc or a 
reading of 0 volts, check for faulty 
control switch and wiring, battery 
cable, ground wire connections 
in pump assembly, and pump 
motor.