Chapter 4 Specication
2 -General Characteristic Parameters
3-Water Cooling Condition
No. Characteristics Test conditions Min. Nom. Max. Unit
1 Operating voltage 360 400 440 VAC
2
Input Power MFSC-2000W 100% Output 6.5 KW
Input Power MFSC-3000W 100% Output 10 KW
3
Operating ambient
temperature
10 40
4
Operating ambient
relative humidity
10 85 %
5 Cooling method Water-cooling
6 Storage temperature -10 60
7 Dimensions 482.6*850*172 (W*D*H) mm
8
Weight MFSC-2000W 72 ±3 kg
Weight MFSC-3000W 80 ±3 kg
No. Characteristics Min. Unit
1 Cooling Method Water Cooling
2
Ambient Temperature
30 30
Chiller Set Temperature
24-26 20-23
3 Hydraulic pressure
≥4
bar
4
MFSC-2000W Water Flow Requirements
20
L/
min
MFSC-3000W Water Flow Requirements
25
5
MFSC-2000W Chiller Rated Cooling Capacity
Requirements
6.5
kw
MFSC-3000W Chiller Rated Cooling Capacity
Requirements
7.5
kw