36
Chapter 7 Fiber Connector Inspection and Cleaning Guide
instructions.
2-Operating Procedures
Clean and maintain the ber laser according to the following procedures:
1
Switch off the laser power, and place the key switch on position of “OFF”
2
Remove the black outer protective sleeve and leave the white inner cap on
and clean the ber connector exterior with optical cleaner, wipe it with a clean
optical wipe and dry it with compressed air;
3
Place ber connector in the holder of the microscope;
7-1
4
Remove the protective inner cap from the connector;
7-2
5
Focus the microscope onto the connector surface;
6
Use a light source to illuminate the face of the fiber connector so that the
light is reflected off the surface of the endface. This is achieved if you see a
bright golden shine from the QBH connector endface.
7
Inspect the endface surface carefully. Contamination will lead to dark
spots/burns on the surface and possibly damage to the fiber and/or laser. If
contamination is visible on the endface, cleaning is necessary.
8
Take out the cap and sleeve, then connect the ber connector with the cutting
head quickly and fasten them. (Place the cap face down on a clean surface or a
lint-free wipe.)
7-1 Take off the protective sleeve and cap of the fiber connector