Function: Switching the digital outputs (v1.0.5 and later)
Port
Parameter
Read
Write
Path
PW2
Prescaler {0,1025}
x
/sys/gpio_board/pwm/prescalar
Pulse {0,65535}
/sys/gpio_board/pwm/1
PW1
Prescaler {0,1025}
x
/sys/gpio_board/pwm/prescalar
Pulse {0,65535}
/sys/gpio_board/pwm/2
Period*{0,11}
x
/sys/gpio_board/pwm/period
*Only if MC100 GPIO board supports Period.
11.6 MC100 SensT2
Digital Inputs 11.6.1
Port
Description
DGND1
Digital Ground1, electrically isolated to all (D)GND
I1 bis I4
Digital inputs
Input voltage: 0 to 30V
Switching threshold: approx. 4V
All input voltages with DGND1 as ground
VPU1
Not supported, please do not connect a signal
DGND2
Digital Ground 2, electrically isolated to all (D)GND
I1 bis I4
Digital inputs
Input voltage: 0 to 30V
Switching threshold: approx. 4V
All input voltages with DGND2 as ground
VPU2
Not supported, please do not connect a signal
Function: Reading the digital inputs I1 to I8 (v1.0.4 and older)
Port
Parameter
Read
Write
Path
I1
1,0
x
/sys/senst2_IO/inputs/input0/value
I2
1,0
x
/sys/senst2_IO /inputs/input1/value
I3
1,0
x
/sys/senst2_IO /inputs/input2/value
I4
1,0
x
/sys/senst2_IO /inputs/input3/value
I5
1,0
x
/sys/senst2_IO /inputs/input4/value
I6
1,0
x
/sys/senst2_IO /inputs/input5/value
I7
1,0
x
/sys/senst2_IO /inputs/input6/value
I8
1,0
x
/sys/senst2_IO /inputs/input7/value
Example: Read out input I1
Command: cat /sys/senst2_IO/inputs/input0/value
Response: e.g. 1# or 0#