MC100
Mobile programmable gateway
MC Technologies GmbH, Kabelkamp 2, 30179 Hannover, Germany
Tel: +49511 67 69 99-0, Fax: +49511 67 69 99-150, Website & Shop: www.mc-technologies.net, Email: info@mc-technologies.net
31
Function: Switching the digital outputs (v1.0.5 and later)
/sys/gpio_board/pwm/prescalar
/sys/gpio_board/pwm/prescalar
/sys/gpio_board/pwm/period
*Only if MC100 GPIO board supports Period.
11.6 MC100 SensT2
Digital Inputs 11.6.1
Digital Ground1, electrically isolated to all (D)GND
Digital inputs
Input voltage: 0 to 30V
Switching threshold: approx. 4V
All input voltages with DGND1 as ground
Not supported, please do not connect a signal
Digital Ground 2, electrically isolated to all (D)GND
Digital inputs
Input voltage: 0 to 30V
Switching threshold: approx. 4V
All input voltages with DGND2 as ground
Not supported, please do not connect a signal
Function: Reading the digital inputs I1 to I8 (v1.0.4 and older)
/sys/senst2_IO/inputs/input0/value
/sys/senst2_IO /inputs/input1/value
/sys/senst2_IO /inputs/input2/value
/sys/senst2_IO /inputs/input3/value
/sys/senst2_IO /inputs/input4/value
/sys/senst2_IO /inputs/input5/value
/sys/senst2_IO /inputs/input6/value
/sys/senst2_IO /inputs/input7/value
Example: Read out input I1
Command: cat /sys/senst2_IO/inputs/input0/value
Response: e.g. 1# or 0#