- 26 -
8-6. Current index (Current measurement)
Each time a Depth calculation is taken, a Current Index simultaneously appears on the display.
*The Current gradually reduces as the distance from the Transmitter increases.
ERR : The line is disconnected.
Or, the current does not travel after the joint of the gas line / water line due to
non-conductivity.
The Current value is not affected by the depth
Depth : 1.90m
Current Index :2.0mA
Depth : 1.75m
Current Index :1.5mA
Depth : 2.00m
Current Index :1.0mA
1.80m
0.7mA
*Normal tracing ® Current value progress down.
Current Value =2.0mA
Current Value =1.5mA
Current Value =1.0mA
0.7mA
1.00m / 2.0mA
30cm
1.00m / 200
1.30m / 200
The current value is not affected by the depth,
but it is affected by the detection methods, the
frequencies and power level.
Leak/ Fault
Disconnect
The current leaks to a ground.